Move types to separate file, start using enum
This commit is contained in:
parent
50978111c5
commit
57709242fa
|
@ -5,65 +5,95 @@ from uuid import uuid4
|
|||
|
||||
import paho.mqtt.client as mqtt
|
||||
|
||||
from solar_types import DataName
|
||||
|
||||
from . import BaseConsumer
|
||||
|
||||
MAP_VALUES: Dict[str, Dict[str, Any]] = {
|
||||
# "battery_voltage_min",
|
||||
# "battery_voltage_max",
|
||||
# "charge_max_current",
|
||||
# "_discharge_max_current?",
|
||||
# "charge_max_power",
|
||||
# "discharge_max_power",
|
||||
# "charge_amp_hour",
|
||||
# "discharge_amp_hour",
|
||||
"production_power": {
|
||||
MAP_VALUES: Dict[DataName, Dict[str, Any]] = {
|
||||
# DataName.BATTERY_VOLTAGE_MIN: {},
|
||||
# DataName.BATTERY_VOLTAGE_MAX: {},
|
||||
# DataName.CHARGE_MAX_CURRENT: {},
|
||||
# DataName._DISCHARGE_MAX_CURRENT: {},
|
||||
# DataName.CHARGE_MAX_POWER: {},
|
||||
# DataName.DISCHARGE_MAX_POWER: {},
|
||||
# DataName.CHARGE_AMP_HOUR: {},
|
||||
# DataName.DISCHARGE_AMP_HOUR: {},
|
||||
DataName.PRODUCTION_ENERGY: {
|
||||
"unit": "Wh",
|
||||
"type": "energy",
|
||||
"state_class": "total_increasing",
|
||||
},
|
||||
"consumption_power": {
|
||||
DataName.CONSUMPTION_ENERGY: {
|
||||
"unit": "Wh",
|
||||
"type": "energy",
|
||||
"state_class": "total_increasing",
|
||||
},
|
||||
# "run_days",
|
||||
# "discharge_count",
|
||||
# "full_charge_count",
|
||||
# "total_charge_amp_hours",
|
||||
# "total_discharge_amp_hours",
|
||||
"total_production_power": {
|
||||
# DataName.RUN_DAYS: {},
|
||||
# DataName.DISCHARGE_COUNT: {},
|
||||
# DataName.FULL_CHARGE_COUNT: {},
|
||||
# DataName.TOTAL_CHARGE_AMP_HOURS: {},
|
||||
# DataName.TOTAL_DISCHARGE_AMP_HOURS: {},
|
||||
DataName.TOTAL_PRODUCTION_ENERGY: {
|
||||
"unit": "Wh",
|
||||
"type": "energy",
|
||||
"state_class": "total_increasing",
|
||||
"expiry": 180,
|
||||
},
|
||||
"total_consumption_power": {
|
||||
DataName.TOTAL_CONSUMPTION_ENERGY: {
|
||||
"unit": "Wh",
|
||||
"type": "energy",
|
||||
"state_class": "total_increasing",
|
||||
"expiry": 180,
|
||||
},
|
||||
#
|
||||
"battery_charge": {"unit": "%", "type": "battery", "state_class": "measurement"},
|
||||
"battery_voltage": {"unit": "V", "type": "voltage", "state_class": "measurement"},
|
||||
"battery_current": {"unit": "A", "type": "current", "state_class": "measurement"},
|
||||
"internal_temperature": {
|
||||
DataName.BATTERY_CHARGE: {
|
||||
"unit": "%",
|
||||
"type": "battery",
|
||||
"state_class": "measurement",
|
||||
},
|
||||
DataName.BATTERY_VOLTAGE: {
|
||||
"unit": "V",
|
||||
"type": "voltage",
|
||||
"state_class": "measurement",
|
||||
},
|
||||
DataName.BATTERY_CURRENT: {
|
||||
"unit": "A",
|
||||
"type": "current",
|
||||
"state_class": "measurement",
|
||||
},
|
||||
DataName.INTERNAL_TEMPERATURE: {
|
||||
"unit": "°C",
|
||||
"type": "temperature",
|
||||
"state_class": "measurement",
|
||||
},
|
||||
"battery_temperature": {
|
||||
DataName.BATTERY_TEMPERATURE: {
|
||||
"unit": "°C",
|
||||
"type": "temperature",
|
||||
"state_class": "measurement",
|
||||
},
|
||||
"load_voltage": {"unit": "V", "type": "voltage", "state_class": "measurement"},
|
||||
"load_current": {"unit": "A", "type": "current", "state_class": "measurement"},
|
||||
"load_power": {"unit": "W", "type": "power", "state_class": "measurement"},
|
||||
"panel_voltage": {"unit": "V", "type": "voltage", "state_class": "measurement"},
|
||||
"panel_current": {"unit": "A", "type": "current", "state_class": "measurement"},
|
||||
"panel_power": {"unit": "W", "type": "power", "state_class": "measurement"},
|
||||
# "load_enabled",
|
||||
DataName.LOAD_VOLTAGE: {
|
||||
"unit": "V",
|
||||
"type": "voltage",
|
||||
"state_class": "measurement",
|
||||
},
|
||||
DataName.LOAD_CURRENT: {
|
||||
"unit": "A",
|
||||
"type": "current",
|
||||
"state_class": "measurement",
|
||||
},
|
||||
DataName.LOAD_POWER: {"unit": "W", "type": "power", "state_class": "measurement"},
|
||||
DataName.PANEL_VOLTAGE: {
|
||||
"unit": "V",
|
||||
"type": "voltage",
|
||||
"state_class": "measurement",
|
||||
},
|
||||
DataName.PANEL_CURRENT: {
|
||||
"unit": "A",
|
||||
"type": "current",
|
||||
"state_class": "measurement",
|
||||
},
|
||||
DataName.PANEL_POWER: {"unit": "W", "type": "power", "state_class": "measurement"},
|
||||
# DataName.LOAD_ENABLED: {},
|
||||
}
|
||||
|
||||
|
||||
|
@ -173,12 +203,13 @@ class MqttConsumer(BaseConsumer):
|
|||
for k, v in data.items():
|
||||
if k in MAP_VALUES:
|
||||
if k not in self.initialized:
|
||||
km = MAP_VALUES[DataName(k)]
|
||||
pretty_name = k.replace("_", " ").capitalize()
|
||||
disc_prefix = self.settings["discovery_prefix"]
|
||||
device_id = self.settings["device_id"]
|
||||
self.client.publish(
|
||||
f"{self.settings['discovery_prefix']}/sensor/{self.settings['device_id']}_{k}/config", # noqa: E501
|
||||
payload=json.dumps(
|
||||
self.get_ha_config(k, pretty_name, **MAP_VALUES[k])
|
||||
),
|
||||
f"{disc_prefix}/sensor/{device_id}_{k}/config",
|
||||
payload=json.dumps(self.get_ha_config(k, pretty_name, **km)),
|
||||
retain=True,
|
||||
)
|
||||
self.initialized.append(k)
|
||||
|
|
|
@ -7,6 +7,8 @@ from typing import Any, Dict
|
|||
|
||||
import rrdtool
|
||||
|
||||
from solar_types import DataName
|
||||
|
||||
DT_FORMAT = "%Y-%m-%d %H:%M:%S.%f"
|
||||
|
||||
START = (
|
||||
|
@ -15,39 +17,39 @@ START = (
|
|||
)
|
||||
# 2021-11-12 16:58:32.262030
|
||||
HISTORICAL_KEYS = {
|
||||
"battery_voltage_min",
|
||||
"battery_voltage_max",
|
||||
"charge_max_current",
|
||||
"_discharge_max_current?",
|
||||
"charge_max_power",
|
||||
"discharge_max_power",
|
||||
"charge_amp_hour",
|
||||
"discharge_amp_hour",
|
||||
"production_power",
|
||||
"consumption_power",
|
||||
"run_days",
|
||||
"discharge_count",
|
||||
"full_charge_count",
|
||||
"total_charge_amp_hours",
|
||||
"total_discharge_amp_hours",
|
||||
"total_production_power",
|
||||
"total_consumption_power",
|
||||
DataName.BATTERY_VOLTAGE_MIN,
|
||||
DataName.BATTERY_VOLTAGE_MAX,
|
||||
DataName.CHARGE_MAX_CURRENT,
|
||||
DataName._DISCHARGE_MAX_CURRENT,
|
||||
DataName.CHARGE_MAX_POWER,
|
||||
DataName.DISCHARGE_MAX_POWER,
|
||||
DataName.CHARGE_AMP_HOUR,
|
||||
DataName.DISCHARGE_AMP_HOUR,
|
||||
DataName.PRODUCTION_ENERGY,
|
||||
DataName.CONSUMPTION_ENERGY,
|
||||
DataName.RUN_DAYS,
|
||||
DataName.DISCHARGE_COUNT,
|
||||
DataName.FULL_CHARGE_COUNT,
|
||||
DataName.TOTAL_CHARGE_AMP_HOURS,
|
||||
DataName.TOTAL_DISCHARGE_AMP_HOURS,
|
||||
DataName.TOTAL_PRODUCTION_ENERGY,
|
||||
DataName.TOTAL_CONSUMPTION_ENERGY,
|
||||
}
|
||||
|
||||
# 2021-11-12 16:58:47.521142
|
||||
INSTANT_KEYS = {
|
||||
"battery_charge",
|
||||
"battery_voltage",
|
||||
"battery_current",
|
||||
"internal_temp",
|
||||
"battery_temp",
|
||||
"load_voltage",
|
||||
"load_current",
|
||||
"load_power",
|
||||
"panel_voltage",
|
||||
"panel_current",
|
||||
"panel_power",
|
||||
"load_enabled",
|
||||
DataName.BATTERY_CHARGE,
|
||||
DataName.BATTERY_VOLTAGE,
|
||||
DataName.BATTERY_CURRENT,
|
||||
DataName.INTERNAL_TEMPERATURE,
|
||||
DataName.BATTERY_TEMPERATURE,
|
||||
DataName.LOAD_VOLTAGE,
|
||||
DataName.LOAD_CURRENT,
|
||||
DataName.LOAD_POWER,
|
||||
DataName.PANEL_VOLTAGE,
|
||||
DataName.PANEL_CURRENT,
|
||||
DataName.PANEL_POWER,
|
||||
DataName.LOAD_ENABLED,
|
||||
}
|
||||
|
||||
KNOWN_KEYS = HISTORICAL_KEYS.union(INSTANT_KEYS)
|
||||
|
|
77
solar_ble.py
77
solar_ble.py
|
@ -6,12 +6,13 @@ import struct
|
|||
import sys
|
||||
import time
|
||||
from io import RawIOBase
|
||||
from typing import Callable, Collection, Optional, cast
|
||||
from typing import Collection, Optional, cast
|
||||
|
||||
from bluepy import btle
|
||||
from libscrc import modbus
|
||||
|
||||
from feasycom_ble import BTLEUart
|
||||
from solar_types import DATA_BATTERY_STATE, HISTORICAL_DATA, DataItem
|
||||
from test_config import get_config, get_consumers
|
||||
|
||||
MAC = "DC:0D:30:9C:61:BA"
|
||||
|
@ -190,59 +191,6 @@ def humanize_number(data, unit: str = ""):
|
|||
return f"{data:.3g} {prefix}{unit}"
|
||||
|
||||
|
||||
class DataItem:
|
||||
name: str
|
||||
st_format: str
|
||||
unit: Optional[str]
|
||||
transformation: Optional[Callable]
|
||||
|
||||
def __init__(
|
||||
self,
|
||||
name: str,
|
||||
st_format: str,
|
||||
unit: Optional[str] = None,
|
||||
transform: Optional[Callable] = None,
|
||||
):
|
||||
self.name = name
|
||||
self.st_format = st_format
|
||||
self.unit = unit
|
||||
self.transformation = transform
|
||||
|
||||
if self.st_format[0] not in "@=<>!":
|
||||
self.st_format = "!" + self.st_format
|
||||
|
||||
@property
|
||||
def st_size(self) -> int:
|
||||
return struct.calcsize(self.st_format)
|
||||
|
||||
def transform(self, data):
|
||||
if self.transformation is None:
|
||||
return data
|
||||
return self.transformation(data)
|
||||
|
||||
|
||||
def parse_temperature(bin):
|
||||
if bin & 0x80:
|
||||
return (bin & 0x7F) * -1
|
||||
return bin & 0x7F
|
||||
|
||||
|
||||
DATA_BATTERY_STATE = [
|
||||
DataItem("battery_charge", "H", "%"),
|
||||
DataItem("battery_voltage", "H", "V", lambda n: n / 10),
|
||||
DataItem("battery_current", "H", "A", lambda n: n / 100),
|
||||
DataItem("internal_temperature", "B", "°C", parse_temperature),
|
||||
DataItem("battery_temperature", "B", "°C", parse_temperature),
|
||||
DataItem("load_voltage", "H", "V", lambda n: n / 10),
|
||||
DataItem("load_current", "H", "A", lambda n: n / 100),
|
||||
DataItem("load_power", "H", "W"),
|
||||
DataItem("panel_voltage", "H", "V", lambda n: n / 10),
|
||||
DataItem("panel_current", "H", "A", lambda n: n / 100),
|
||||
DataItem("panel_power", "H", "W"),
|
||||
DataItem("load_enabled", "x?", transform=bool),
|
||||
]
|
||||
|
||||
|
||||
def parse(data: bytes, items: Collection[DataItem], offset: int = 0) -> dict:
|
||||
pos = offset
|
||||
res = {}
|
||||
|
@ -259,27 +207,6 @@ def parse_battery_state(data: bytes) -> dict:
|
|||
return parse(data, DATA_BATTERY_STATE)
|
||||
|
||||
|
||||
HISTORICAL_DATA = [
|
||||
DataItem("battery_voltage_min", "H", "V", lambda n: n / 10),
|
||||
DataItem("battery_voltage_max", "H", "V", lambda n: n / 10),
|
||||
DataItem("charge_max_current", "H", "A", lambda n: n / 100),
|
||||
DataItem("_discharge_max_current?", "H", "A", lambda n: n / 100),
|
||||
DataItem("charge_max_power", "H", "W"),
|
||||
DataItem("discharge_max_power", "H", "W"),
|
||||
DataItem("charge_amp_hour", "H", "Ah"),
|
||||
DataItem("discharge_amp_hour", "H", "Ah"),
|
||||
DataItem("production_power", "H", "Wh"),
|
||||
DataItem("consumption_power", "H", "Wh"),
|
||||
DataItem("run_days", "H"),
|
||||
DataItem("discharge_count", "H"),
|
||||
DataItem("full_charge_count", "H"),
|
||||
DataItem("total_charge_amp_hours", "L", "Ah"),
|
||||
DataItem("total_discharge_amp_hours", "L", "Ah"),
|
||||
DataItem("total_production_power", "L", "Wh"),
|
||||
DataItem("total_consumption_power", "L", "Wh"),
|
||||
]
|
||||
|
||||
|
||||
def parse_historical_entry(data: bytes) -> dict:
|
||||
res = parse(data, HISTORICAL_DATA[:10])
|
||||
|
||||
|
|
|
@ -0,0 +1,114 @@
|
|||
# -*- coding: utf-8 -*-
|
||||
import struct
|
||||
from enum import Enum, unique
|
||||
from typing import Callable, Optional
|
||||
|
||||
|
||||
@unique
|
||||
class DataName(str, Enum):
|
||||
BATTERY_CHARGE = "battery_charge"
|
||||
BATTERY_VOLTAGE = "battery_voltage"
|
||||
BATTERY_CURRENT = "battery_current"
|
||||
INTERNAL_TEMPERATURE = "internal_temperature"
|
||||
BATTERY_TEMPERATURE = "battery_temperature"
|
||||
LOAD_VOLTAGE = "load_voltage"
|
||||
LOAD_CURRENT = "load_current"
|
||||
LOAD_POWER = "load_power"
|
||||
PANEL_VOLTAGE = "panel_voltage"
|
||||
PANEL_CURRENT = "panel_current"
|
||||
PANEL_POWER = "panel_power"
|
||||
LOAD_ENABLED = "load_enabled"
|
||||
BATTERY_VOLTAGE_MIN = "battery_voltage_min"
|
||||
BATTERY_VOLTAGE_MAX = "battery_voltage_max"
|
||||
CHARGE_MAX_CURRENT = "charge_max_current"
|
||||
_DISCHARGE_MAX_CURRENT = "_discharge_max_current?"
|
||||
CHARGE_MAX_POWER = "charge_max_power"
|
||||
DISCHARGE_MAX_POWER = "discharge_max_power"
|
||||
CHARGE_AMP_HOUR = "charge_amp_hour"
|
||||
DISCHARGE_AMP_HOUR = "discharge_amp_hour"
|
||||
PRODUCTION_ENERGY = "production_energy"
|
||||
CONSUMPTION_ENERGY = "consumption_energy"
|
||||
RUN_DAYS = "run_days"
|
||||
DISCHARGE_COUNT = "discharge_count"
|
||||
FULL_CHARGE_COUNT = "full_charge_count"
|
||||
TOTAL_CHARGE_AMP_HOURS = "total_charge_amp_hours"
|
||||
TOTAL_DISCHARGE_AMP_HOURS = "total_discharge_amp_hours"
|
||||
TOTAL_PRODUCTION_ENERGY = "total_production_energy"
|
||||
TOTAL_CONSUMPTION_ENERGY = "total_consumption_energy"
|
||||
|
||||
def __repr__(self):
|
||||
return repr(self.value)
|
||||
|
||||
|
||||
class DataItem:
|
||||
name: DataName
|
||||
st_format: str
|
||||
unit: Optional[str]
|
||||
transformation: Optional[Callable]
|
||||
|
||||
def __init__(
|
||||
self,
|
||||
name: DataName,
|
||||
st_format: str,
|
||||
unit: Optional[str] = None,
|
||||
transform: Optional[Callable] = None,
|
||||
):
|
||||
self.name = name
|
||||
self.st_format = st_format
|
||||
self.unit = unit
|
||||
self.transformation = transform
|
||||
|
||||
if self.st_format[0] not in "@=<>!":
|
||||
self.st_format = "!" + self.st_format
|
||||
|
||||
@property
|
||||
def st_size(self) -> int:
|
||||
return struct.calcsize(self.st_format)
|
||||
|
||||
def transform(self, data):
|
||||
if self.transformation is None:
|
||||
return data
|
||||
return self.transformation(data)
|
||||
|
||||
|
||||
def parse_temperature(bin):
|
||||
if bin & 0x80:
|
||||
return (bin & 0x7F) * -1
|
||||
return bin & 0x7F
|
||||
|
||||
|
||||
DATA_BATTERY_STATE = [
|
||||
DataItem(DataName.BATTERY_CHARGE, "H", "%"),
|
||||
DataItem(DataName.BATTERY_VOLTAGE, "H", "V", lambda n: n / 10),
|
||||
DataItem(DataName.BATTERY_CURRENT, "H", "A", lambda n: n / 100),
|
||||
DataItem(DataName.INTERNAL_TEMPERATURE, "B", "°C", parse_temperature),
|
||||
DataItem(DataName.BATTERY_TEMPERATURE, "B", "°C", parse_temperature),
|
||||
DataItem(DataName.LOAD_VOLTAGE, "H", "V", lambda n: n / 10),
|
||||
DataItem(DataName.LOAD_CURRENT, "H", "A", lambda n: n / 100),
|
||||
DataItem(DataName.LOAD_POWER, "H", "W"),
|
||||
DataItem(DataName.PANEL_VOLTAGE, "H", "V", lambda n: n / 10),
|
||||
DataItem(DataName.PANEL_CURRENT, "H", "A", lambda n: n / 100),
|
||||
DataItem(DataName.PANEL_POWER, "H", "W"),
|
||||
DataItem(DataName.LOAD_ENABLED, "x?", transform=bool),
|
||||
]
|
||||
|
||||
|
||||
HISTORICAL_DATA = [
|
||||
DataItem(DataName.BATTERY_VOLTAGE_MIN, "H", "V", lambda n: n / 10),
|
||||
DataItem(DataName.BATTERY_VOLTAGE_MAX, "H", "V", lambda n: n / 10),
|
||||
DataItem(DataName.CHARGE_MAX_CURRENT, "H", "A", lambda n: n / 100),
|
||||
DataItem(DataName._DISCHARGE_MAX_CURRENT, "H", "A", lambda n: n / 100),
|
||||
DataItem(DataName.CHARGE_MAX_POWER, "H", "W"),
|
||||
DataItem(DataName.DISCHARGE_MAX_POWER, "H", "W"),
|
||||
DataItem(DataName.CHARGE_AMP_HOUR, "H", "Ah"),
|
||||
DataItem(DataName.DISCHARGE_AMP_HOUR, "H", "Ah"),
|
||||
DataItem(DataName.PRODUCTION_ENERGY, "H", "Wh"),
|
||||
DataItem(DataName.CONSUMPTION_ENERGY, "H", "Wh"),
|
||||
DataItem(DataName.RUN_DAYS, "H"),
|
||||
DataItem(DataName.DISCHARGE_COUNT, "H"),
|
||||
DataItem(DataName.FULL_CHARGE_COUNT, "H"),
|
||||
DataItem(DataName.TOTAL_CHARGE_AMP_HOURS, "L", "Ah"),
|
||||
DataItem(DataName.TOTAL_DISCHARGE_AMP_HOURS, "L", "Ah"),
|
||||
DataItem(DataName.TOTAL_PRODUCTION_ENERGY, "L", "Wh"),
|
||||
DataItem(DataName.TOTAL_CONSUMPTION_ENERGY, "L", "Wh"),
|
||||
]
|
Loading…