mirror of
https://github.com/markqvist/RNode_Firmware.git
synced 2026-04-27 14:30:33 +00:00
Add BHI260 init retry, revert BMM150 firmware (no magnetometer on PCB)
The T-Watch Ultra does not have a BMM150 magnetometer — the BHI260AP aux I2C pins are tied to VDD1V8 (confirmed from schematic). The BOSCH_BHI260_AUX_BMM150_GPIO firmware fails to init because there is no BMM150 to discover. Reverted to BOSCH_BHI260_GPIO. Added 10s retry interval for BHI260 init failures instead of single-attempt with no recovery.
This commit is contained in:
parent
a45986f7a4
commit
7208ce348c
1 changed files with 6 additions and 2 deletions
|
|
@ -2221,9 +2221,13 @@ void loop() {
|
|||
// Deferred BHI260AP init — runs once after boot is complete
|
||||
// Firmware upload takes ~10s and blocks, so we do it after radio is up
|
||||
#if BOARD_MODEL == BOARD_TWATCH_ULT
|
||||
if (!bhi260_ready && bhi260 == NULL && millis() > 5000) {
|
||||
static uint32_t bhi260_next_try = 5000;
|
||||
if (!bhi260_ready && millis() > bhi260_next_try) {
|
||||
bhi260_next_try = millis() + 10000; // retry every 10s
|
||||
if (bhi260 == NULL) {
|
||||
bhi260 = new SensorBHI260AP();
|
||||
}
|
||||
Wire.setClock(1000000UL);
|
||||
bhi260 = new SensorBHI260AP();
|
||||
bhi260->setPins(-1);
|
||||
bhi260->setFirmware(bosch_firmware_image, bosch_firmware_size, false);
|
||||
bhi260->setBootFromFlash(false);
|
||||
|
|
|
|||
Loading…
Add table
Add a link